Home | Products & Technical Documents | Contact Us | News/Case Studies | Representative Customer List | Search

  Products

  DISTRIBUTORS OF THE:
     (The following information is provided by the OEMs of the equipment)
 

PREVAC AquaPower

This unit is a permanently installed refrigerant pressure controlled system for idle R-11 & R-123 chillers that circulate heated water through the evaporator for:  1. Pressure sealing a chiller during idle periods to prevent chiller downtime, prevent refrigerant contamination and acid damage, and eliminate hard start-ups and improve reliability.  2. Push-button pressurization to enable service personnel to conform to EPA, ASHRAE, NEC & Local Building Codes when leak testing, perform minor repairs at 0.00psig to prevent refrigerant losses in compliance with EPA Clean Air Act, Improve response time for leak repairs to minimize downtime, and repair leaks fast to eliminate non-condensables, higher head pressures and wasted energy.  3. Chiller over-pressurization warning and pressure reducing capability to notify operating personnel before rupture disc bursts and initiate corrective actions before the rupture disc bursts.

 


Permanently installed refrigerant pressure control system for idle R-11/R-123 chillers that circulates heated water through the evaporator for:
PREVAC AquaPower
(PREvention of VACuum)

Over 10,000 Systems
Installed
Worldwide

 

View Brochure Front page

View Brochure Back page

    Pressure Sealing a chiller during idle periods to:
  • Prevent chiller downtime
  • Prevent refrigerant contamination and acid damage.
  • Eliminate hard start-ups and improve reliability
    Push-Button Pressurization To:
  • Enable service personnel to conform to EPA, ASHRAE, NEC and local building codes when leak testing
  • Perform minor repairs at 0.00 psig to prevent refrigerant loses in compliance with EPA Clean Air Act
  • Improve response time for leak repairs to minimize downtime
  • Repair leaks fast to eliminate non-condensables, higher head pressures and wasted energy
    Chiller Over-Pressurization Warning and Pressure Reducing Capability To:
  • Notify operating personnel before a rupture disc bursts
  • Initiate corrective actions before the rupture bursts, not after!

 

Quick Pressure Portable

This unit, with the -Never Burst Protection,- is a state of the art pressurizing system which provides unparalleled performance and safety in raising the water temperature inside the evaporator of a low pressure centrifugal chiller for the purpose of leak testing and performing minor repairs at zero in compliance with the EPA Clean Air Act.

Quick Pressure Portable

 

View Brochure
    Quick Pressure benefits...
  • 22,600 watts of power.
  • Allows fast, frequent, not-disruptive leak testing.
  • Allows minor repairs to be performed at 0 psig.
  • Easily handled by one person.
  • Pump can be operated independently of heaters.
  • Temperature and pressure controlled.
  • Utilizes low cost, easily accessible, standard stock heaters.
  • Requires only one supply voltage for all components.
  • Rustproof, stainless steel construction.
  • Now available fully assembled, just bring your own hoses.
    (Also available as a ready-to-assemble kit)

Contact Us for Additional Information

Back to top Back To Top

Redi Controls Inc. Copyright 2003    All Rights Reserved