Safety Relief Valves and Rupture Alarm

The RuptureSeal Series (For Low Pressure Centrifugal Chillers only).

The primary function of the RuptureSeal  SAFETY RELIEF VALVE is to minimize refrigerant loss to the atmosphere in the event of chiller over-pressurization.  The RuptureSeal SAFETY RELIEF VALVE  accomplishes this vital function by automatically re-closing the vent path once the over-pressurized chiller begins returning to its normal operating pressure.

The RuptureSeal RS Series Backup Relief Valves, with their patented collection trap, can be installed utilizing the chillers existing carbon rupture disk and thus can be installed without having to shut down the chiller or pull its refrigerant charge.

Model RS-2 Specifications     Manual     Bid Spec Guide      Performance Chart    Brochure
Model RS-3
Specifications    
Manual     Bid Spec Guide      Performance Chart    Brochure
                                               News Articles & Case Studies

          The RutureSeal NRS Series Backup Relief Valves include a non-fragmenting reverse-buckling solid metal rupture disk which mounts directly to the chiller’s existing rupture disk flange.

Model NRS-2 Specifications     Manual     Bid Spec Guide    Performance Chart    Brochure
Model NRS-3
 Specifications     Manual     Bid Spec Guide    Performance Chart    Brochure
                                                  News Articles & Case Studies
   

The RuptureAlarm is designed to be used with a RuptureSeal backup relief valve.  The function of the RuptureAlarm is to alert the operator that an over-pressurization condition has occurred due to a burst rupture disk, or there is pressure build up between the RuptureSeal and the rupture disk due to leakage through a defective rupture disk.

The RuptureAlarm will activate when the preset (operator adjustable) pressure setting is exceeded providing a visual alarm to the operator.  The visual indication (a neon lamp) will remain latched ON until manually canceled, even if the pressure subsides.  The neon lamp remains activated to insure that the operator is made aware that an alarm event has occurred.
The RuptureAlarm also provides a set of SPDT contacts for remote alarm.

    RuptureAlarm RA 2-3                                                               Specifications        Manual
    RuptureAlarm RA 2-3 international                                      Specifications        Manual

 

 